搜索结果

搜索类型:
Found 100 results containing the words:node
  • 根据国际标准校准电气安全测试仪

    EN 50191,有关电气测试设备安装和运行的电气安全测试标准

    文章
  • 工业/现场温度校准器选择指南

    温度是很多工业流程的重要参数,定期进行校准,可以提高温度测量的准确度。校准过程需要一个热源来提供稳定的温场。福禄克计量校准部可以提供多种干式炉、微型油槽和红外校准器,用于工业和过程行业的温度校准。

    文章
  • 温度基标准选择指南

    ITS-90温标定义的基标准是SPRT和定义固定点。SPRT在固定点瓶内进行校准可以提供非常高的温度准确度。福禄克提供的SPRT,固定点瓶及其他设备能够溯源到ITS-90温标

    文章
  • 测温仪选择指南

    福禄克计量校准部的数字测温仪可以进高精度测温,用于校准工作。测温仪的原理是测量电压值或电阻值,然后将测得的值转换成温度进行显示。

    文章
  • Frequently Asked Questions for Temperature Calibration Software

    Quick Links-Download Demos, Updates, Service Releases, etc.Technical SupportQuestions about Fluke Calibration Temperature software? This page answers some of the most common questions concerning our software products.All Fluke Calibration temperature calibration software:Q. What version of Windows® is required to run Fluke Calibration Temperature software?A. Please refer to the table below for Windows® compatibility information for the latest version of each software indicated: Software \ Windows®98/98SENT4...

    文章
  • Why is Calibration Important?

    Table of ContentsWhy is calibration important?The importance of calibration in the futureDifferent perspectives on the significance of calibrationThe benefits and purpose of calibrationWhat are the costs and risks of not calibrating?Summary / TL;DRWhy is calibration important?Calibration is important because it helps ensure accurate measurements, and accurate measurements are foundational to the quality, safety and innovation of most products and services we use and rely on every day.Few people realize...

    文章
  • 关于校准

    让BIPM在全球范围内管理SI的主要好处是校准的互操作性。这意味着,世界各地都在使用相同的测量系统和定义。这样,美国的某人在澳大利亚购买一个1欧姆的电阻,并确信按照美国的标准对其进行测量时也为1欧姆,反之亦然。为了实现互操作性,我们需要所有的测量结果都可溯源至同一定义。

    文章
  • A40/A40A 分流器

    A40 系列由 12 个分流器组成,其额定值从 10 mA 到 5 A。A40A 分流器增加了 10 A 和 20 A 量程。

    产品
  • World Metrology Day celebrates “Measurements in daily life”

    Annual global event highlights why measurement matters in everyday lifeEverett, Wash., May 20, 2013 – On May 20th, scientists and organizations dedicated to metrology celebrate World Metrology Day, which commemorates the signing of the international treaty to coordinate weights and measures activities and support the development of the metric system. Fluke Corporation recognizes World Metrology Day as a time to appreciate the scientists in national laboratories throughout the world who dedicate...

    文章
  • 8588A 标准数字多用表

    专为一级标准实验室设计的福禄克8588A标准数字多用表。点击此处获取详细指标及更多信息。

    产品
  • 8558A八位半数字多用表

    福禄克8558A八位半数字多用表提供5MS/s的高分辨率数字化采样,适用于实验室和制造测试环境下的系统自动化。点击此处获取详细指标及更多信息。

    产品
  • MET/TEMP II Software Download

    MET/TEMP II Software Download (.exe)TITLEVERLinksMET/TEMP II5.2Product PageDescriptionWhen downloaded, this file can be run to install MET/TEMP II. There is no free demo/trial version of 5.2. In order to install MET/TEMP II v5.2, you must purchase the software and obtain a serial number. The installation process prompts you to enter the serial number. Version 5.2 does not accept serial numbers from previous versions of MET/TEMP II. The serial number will be located on a sticker on the CD pouch....

    文章
  • MET/TEAM® v3.3.0 and MET/CAL® v11.0.0 Software Trial

    Release: MET/TEAM version 3.1.1 (with MET/CAL version 10.5.0) (.iso)Documents:MET/CAL 10.5.0 Readme (.pdf)MET/TEAM Installation Guide (.pdf)MET/TEAM 3.1.1 Readme (.pdf)Update Instructions for MET/TEAM 3.1.1 and MET/CAL 10.5.0 (.pdf)This update is not for MET/CONNECT Customers. Current MET/TEAM Customers: What you need to know prior to updatingThe MET/TEAM version 3.1.1 release is a a minor update to MET/TEAM software. This update includes new features, improvements, bug fixes, and minor updates.You...

    文章
  • MET/TEAM version 2.2 (with MET/CAL version 9.1)

    MET/TEAM version 2.2 (with MET/CAL version 9.1) (.iso)Documents:MET/CAL 9.1.0 Readme (.pdf)MET/TEAM 2.2.0 Readme (.pdf)Updating to MET/TEAM 2.2 and MET/CAL 9.1 (.pdf)Current MET/TEAM Customers: What you need to know prior to updatingThere has been a major change to the MET/TEAM database which means updating to version 2.2 is a multistep process that could take from 8 to 24 hours depending on your database, server configuration, and network environment.There has been a major change to MET/CAL regarding...

    文章
  • Update: MET/CAL version 10.6.2 for MET/TEAM version 3.2.0

    Update: MET/CAL version 10.6.2 for MET/TEAM version 3.2.0 (.zip)Documents:Accuracy Files for Fluke 5540A, 5550A, and 5560A (.zip)This update is not for MET/CONNECT Customers. The MET/CONNECT version of this release is available here.Current MET/TEAM Customers:MET/CAL version 10.6.2 release is an update to previous MET/CAL software. This update includes new Instrument FSCs for the Fluke 5560A, 5550A, and 5540A calibrators and bug fixes.Do not manually uninstall the previous version. If you do this...

    文章
  • Update: MET/CAL version 10.6.2 for MET/CONNECT version 2.1.0

    Update: MET/CAL version 10.6.2 for MET/CONNECT version 2.1.0 (.zip)Documents:Accuracy Files for Fluke 5540A, 5550A, and 5560A (.zip)This update is not for MET/TEAM Customers. The MET/TEAM version of this release is available here.Current MET/CONNECT Customers:MET/CAL version 10.6.2 release is an update to previous MET/CAL software. This update includes new Instrument FSCs for the Fluke 5560A, 5550A, and 5540A calibrators and bug fixes.Do not manually uninstall the previous version. If you do this...

    文章
  • Update: MET/CAL version 10.6.1 for MET/TEAM version 3.2.0

    Update: MET/CAL version 10.6.1 for MET/TEAM version 3.2.0 (.zip)This update is not for MET/CONNECT Customers. The MET/CONNECT version of this release is available here.Current MET/TEAM Customers:MET/CAL version 10.6.1 release is an update to previous MET/CAL software. This update includes bug fixes and minor changes.Do not manually uninstall the previous version. If you do this before attempting to install this version, you may lose other information and files.If you have installed MET/CAL Runtime...

    文章
  • Update: MET/CAL version 10.6.1 for MET/CONNECT version 2.1.0

    Update: MET/CAL version 10.6.1 for MET/CONNECT version 2.1.0 (.zip)This update is not for MET/TEAM Customers. The MET/TEAM version of this release is available here.Current MET/CONNECT Customers:MET/CAL version 10.6.1 release is an update to previous MET/CAL software. This update includes bug fixes and minor changes.Do not manually uninstall the previous version. If you do this before attempting to install this version, you may lose other information and files.If you have installed MET/CAL Runtime...

    文章
  • Update: MET/CAL version 10.5.1 for MET/TEAM version 3.1.1 or 3.1.0

    Update: MET/CAL version 10.5.1 for MET/TEAM version 3.1.1 or 3.1.0 (.zip)This update is not for MET/CONNECT Customers. Current MET/TEAM Customers:MET/CAL version 10.5.1 release is an update to previous MET/CAL software. This update includes bug fixes and minor changes.Do not manually uninstall the previous version. If you do this before attempting to install this version, you may lose other information and files.If you have installed MET/CAL Runtime and/or MET/CAL Editor on any workstations, be...

    文章
  • Update: MET/CAL version 10.5.0 for MET/CONNECT version 2.0.0

    Update: MET/CAL version 10.5.0 for MET/CONNECT version 2.0.0 (.zip)This update is not for MET/TEAM Customers. The MET/TEAM version of this release is available with the MET/TEAM 3.1.0 installer.Current MET/CONNECT Customers:MET/CAL version 10.5.0 release is an update to previous MET/CAL software. This update includes new features, bug fixes, and minor updates.Do not manually uninstall the previous version. If you do this before attempting to install this version, you may lose other information and...

    文章
  • Update: MET/CAL version 10.4.0 for MET/TEAM version 3.0.0

    Update: MET/CAL version 10.4.0 for MET/TEAM version 3.0.0 (.zip)This update is not for MET/CONNECT Customers. The MET/CONNECT version of this release is available with the MET/CONNECT 2.0.0 installer.Current MET/TEAM Customers:MET/CAL version 10.4.0 release is an update to previous MET/CAL software. This update includes new features, bug fixes, and minor updates.You must install MET/TEAM version 3.0.0 Hot Fix 2 to use MET/CAL 10.4.0.Do not manually uninstall the previous version. If you do this...

    文章
  • Update: MET/CAL version 10.2.2 for MET/TEAM version 3.0.0

    Update: MET/CAL version 10.2.2 for MET/TEAM version 3.0.0 (.zip)This update is not for MET/CONNECT Customers. The MET/CONNECT version of this release is available with the MET/CONNECT 1.2.0 installer.Current MET/TEAM Customers:MET/CAL version 10.2.2 release is an update to previous MET/CAL software. This update includes bug fixes and minor updates.Do not manually uninstall the previous version. If you do this before attempting to install this version, you may lose other information and files.If you...

    文章
  • Update: MET/CAL version 10.1.1 for MET/TEAM 2.3.0

    Update: MET/CAL version 10.1.1 for MET/TEAM 2.3.0 (.zip)Documents:MET/CAL 10.1.1 Readme (.pdf)This update does not impact MET/CONNECT Customers. It includes the existing Hot Fix for MET/CAL version 10.1.0.Current MET/TEAM Customers:MET/CAL version 10.1.1 release is an update to previous MET/CAL software. This update includes bug fixes and minor updates.Do not manually uninstall the previous version. If you do this before attempting to install this version, you may lose other information and files.If...

    文章
  • RPM4-AD v1.00f Embedded Software

    RPM4-AD v1.00f Embedded Software (.bin)TITLEVERUSE WITHNOT FOR USE WITHRPM4-AD™1.00f2010.12.28RPM4-ADDo NOT use with NON "-AD" (Air Data)RPM4 ModelsInstructions:Download the file.Run Winflash and select the file downloaded as the file to write to the product.Make sure the correct COM port of the product is connected to a RS232 port on the host PC. Use a null modem cable to COM2 port of PG7000 Piston Gauge. Use a standard RS232 cable to COM1 port of PPC, PPC, RPM and molbox.If your product has an...

    文章
  • RPM3 v1.02j Embedded Software

    RPM3 v1.02j Embedded Software (.bin)TITLEVERUSE WITHRPM3™1.02j2005.06.27RPM3Instructions:Do Not use with HGC-30000-AF!Download the file.Run Winflash and select the file downloaded as the file to write to the product.Make sure the correct COM port of the product is connected to a RS232 port on the host PC. Use a null modem cable to COM2 port of PG7000 Piston Gauge. Use a standard RS232 cable to COM1 port of PPC, PPC, RPM and molbox.If your product has an model number ending in "-AF", it requires...

    文章
  • Release: MET/TEAM version 3.3.0 (with MET/CAL version 11.0.0)

    Release: MET/TEAM version 3.3.0 (with MET/CAL version 11.0.0) (.iso)Documents:MET/TEAM 3.3.0 Readme (.pdf)MET/TEAM Installation Guide (.pdf)MET/CAL 11.0.0 Read Me (.pdf)Updating to METTEAM 3.3.0 and METCAL 11.0.0 (.pdf)Current MET/TEAM Customers: What you need to know prior to updatingThe MET/TEAM version 3.3.0 release is a minor update to MET/TEAM software. The MET/CAL version 11.0.0 release is a major update to MET/CAL software. This update includes new features, improvements, bug fixes, and minor...

    文章
  • Release: MET/TEAM version 3.2.0 (with MET/CAL version 10.6.0)

    Release: MET/TEAM version 3.2.0 (with MET/CAL version 10.6.0) (.iso)This update is not for MET/CONNECT Customers. Current MET/TEAM Customers: What you need to know prior to updatingThe MET/TEAM version 3.2.0 release is a a minor update to MET/TEAM software. This update includes new features, improvements, bug fixes, and minor updates.You may upgrade from version 3.0.0, 3.1.0, or 3.1.1 directly to version 3.2.0.Upgrading from version 3.x.x of MET/TEAM will not require you to re-request your licenses.Upgrading...

    文章
  • Release: MET/TEAM version 3.1.1 (with MET/CAL version 10.5.0)

    Release: MET/TEAM version 3.1.1 (with MET/CAL version 10.5.0) (.iso)This update is not for MET/CONNECT Customers. Current MET/TEAM Customers: What you need to know prior to updatingThe MET/TEAM version 3.1.1 release is a a minor update to MET/TEAM software. This update includes new features, improvements, bug fixes, and minor updates.You may upgrade from either version 3.0.0 or 3.1.0 directly to version 3.1.1.Upgrading from version 3.0.0 or 3.1.0 of MET/TEAM will not require you to re-request your...

    文章
  • Release: MET/TEAM version 3.1.0 (with MET/CAL version 10.5.0)

    Release: MET/TEAM version 3.1.0 (with MET/CAL version 10.5.0) (.iso)Documents:MET/TEAM 3.1.0 Readme (.pdf)MET/CAL 10.5.0 Readme (.pdf)MET/TEAM Installation Guide (.pdf)Update Instructions for MET/TEAM 3.1.0 and MET/CAL 10.5.0 (.pdf)This update is not for MET/CONNECT Customers. The MET/CONNECT version of this release is available here.Current MET/TEAM Customers: What you need to know prior to updatingThe MET/TEAM version 3.1.0 and MET/CAL version 10.5.0 release is a a major update to MET/TEAM and...

    文章
  • Release: MET/CAL version 10.1.0 for MET/TEAM 2.3.0

    Release: MET/CAL version 10.1.0 for MET/TEAM 2.3.0 (.zip)Current MET/TEAM Customers:MET/CAL version 10.1.0 release is an update to previous MET/CAL software. This update includes bug fixes and minor updates.Do not manually uninstall the previous version. If you do this before attempting to install this version, you may lose other information and files.If you have installed MET/CAL Runtime and/or MET/CAL Editor on any workstations, be sure to run the MET/CAL Client installer on all MET/CAL workstations...

    文章
  • PPC4E v1.2.6.15 Embedded Software

    PPC4E v1.2.6.15 Embedded Software (.bin)TITLEVERUSE WITHPPC4E™1.2.6.15PPC4EInstructions:Download the file by clicking on "PPC4E v1.2.6.15.bin".Run Winflash and select the file downloaded as the file to write to the product.Make sure the correct COM port of the product is connected to a RS232 port on the host PC. Use a null modem cable to COM2 port of PG7000 Piston Gauge. Use a standard RS232 cable to COM1 port of PPC, PPC, RPM and molbox.If your product has an model number ending in "-AF", it...

    文章
  • PPC4 v1.2.6.14 Embedded Software

    PPC4 v1.2.6.14 Embedded Software (.bin)TITLEVERUSE WITHPPC4™1.2.6.14PPC4 (including -AF models)Instructions:Download the file by clicking on "PPC4 v1.2.6.14.bin".Run Winflash and select the file downloaded as the file to write to the product.Make sure the correct COM port of the product is connected to a RS232 port on the host PC. Use a null modem cable to COM2 port of PG7000 Piston Gauge. Use a standard RS232 cable to COM1 port of PPC, PPC, RPM and molbox.The updating of embedded software should...

    文章
  • PPC2-AF v1.01e Embedded Software

    PPC2-AF v1.01e Embedded Software (222.5 KB)TITLEVERUSE WITHPPC2-AF™1.01e2006.11.17PPC2-AFTITLEVERUSE WITHPPC2-AF™1.01e2006.11.17PPC2-AFInstructions:Do Not use with PPC2+!This software revision affects only the PPC2-AF on-board routines for calibration of the PPC2-AF's RPTs. It has no effect on regular operation. This new release is recommended for all PPC2-AF units, in particular those on which difficulty with calibration of the Lo Reference Pressure Transducer has been encountered. The FCAL...

    文章
  • Fluke 9500C 高性能示波器校准器

    使用 Fluke 9500C 可实现最高 4GHz 的示波器精确校准。采用有源信号头™技术,可实现高效、自动化的多通道校准。

    产品
  • 732C 和 734C 直流电压参考标准器

    利用 734C,确立和维护您实验室中的主要电压标准器非常简单。随着时间的推移,通过对四个装置进行频繁对比以及对其中一个或多个装置进行定期校准,您可以将 734C 的不确定性降低三倍。

    产品
  • molbox1+ or molbox1+S v6.01 Embedded Software

    molbox1+ or molbox1+S v6.01 Embedded Software (.bin)TITLEVERUSE WITHmolbox1+/molbox1+S™6.012016.12.16molbox1+/molbox1+STITLEVERUSE WITHmolbox1+/molbox1+S™6.012016.12.16molbox1+/molbox1+SThis flash is intended ONLY for molbox1+ or molbox1+S with the Fluke Calibration logo: on the front panel, serial number 2000 and above. Attempted use on any other molbox will result in an inoperable molbox unless the molbox1 hardware is upgraded to a molbox1+.For a molbox1 WITHOUT the Fluke Calibration logo,...

    文章
  • molbox1 v5.41 Embedded Software

    molbox1 v5.41 Embedded Software (.bin)TITLEVERUSE WITHmolbox1™5.412016.12.16molbox1TITLEVERUSE WITHmolbox1™5.412016.12.16molbox1Instructions:Download the file.Run Winflash and select the file downloaded as the file to write to the product.Make sure the correct COM port of the product is connected to a RS232 port on the host PC. Use a null modem cable to COM2 port of PG7000 Piston Gauge. Use a standard RS232 cable to COM1 port of PPC, PPC, RPM and molbox.The updating of embedded software should...

    文章
  • IR Configuration Utility v1.0

    IR Configuration Utility v1.0 (.exe)IR Configuration Utility v1.0Posted: 01/23/2009Description: The IR Configuration Utility is shipped with supported instruments. Supported instruments include the 4180 and 4181 Precision IR Calibrators.This software is free and does not require a serial number to be installed.Size: 13.9MB

    文章
  • IO Toolkit v1.0

    IO Toolkit v1.0 (.exe)IO Toolkit (Model 9940)IO Toolkit v1.0Posted: 09/26/2008Description: The IO Toolkit is shipped with supported instruments. This version includes support for the new 1523 and 1524 series Readouts.This software is free and does not require a serial number to be installed.Size: 7.0MB

    文章
  • Hot Fix: MET/TEAM version 2.3.0 Hot Fix 2

    Hot Fix: MET/TEAM version 2.3.0 Hot Fix 2 (.zip)This Hot Fix is to resolve an issue that causes failures to save MET/CAL results data when using Windows Authentication. If you do not use Windows Authentication, this is not a necessary update.Current MET/TEAM Customers:The MET/TEAM 2.3.0 Hot Fix 2 release is an update to previous MET/TEAM software. This update includes bug fixes only.This download does not include an installer. The included files must be manually copied to the appropriate locations...

    文章
  • Hot Fix: MET/CAL version 10.2.2 Hot Fix

    Hot Fix: MET/CAL version 10.2.2 Hot Fix (.zip)Documents:MET/CAL version 10.2.2 Hot Fix Readme (.pdf)This hot fix applies to both MET/TEAM and MET/CONNECT versions of MET/CAL.Current MET/CAL Customers:The MET/CAL 10.2.2 Hot Fix release is an update to previous MET/CAL software. This update includes bug fixes only.This download does not include an installer. The included files must be manually copied to the appropriate locations on each MET/CAL Client PC.Do not uninstall MET/CAL 10.2.2.Follow the instructions...

    文章
  • 5430 高精度标准电阻

    5430 系列中的六个电阻器覆盖了从1Ω到10000Ω的电阻值。每个电阻器的实际电阻与其标称值相差在10ppm之内,且其电阻的变化在2ppm/年以内

    产品
  • FlukeView® Forms Demo/Reader Software Downloads

    FlukeView® Forms Demo/Reader Software Downloads (.exe)You can download the free Demo/Reader version of FlukeView® Forms from this page. It allows you to open any FlukeView® Forms file and view or edit data that has been saved by a FlukeView® Forms user. It also allows you to see how data can be displayed, formatted, printed and saved in FlukeView® Forms.This demonstration software does not include the FlukeView® Forms Designer, which allows you to customize your forms.System Requirements for...

    文章
  • COMPASS® for Pressure Version 3 Release Notes

    Download COMPASS® for PressureVersion 3 Releases3.00.43 (SP1) (2011.02.11)ADDCP-802Support PG7000 and PG9000 models that respond with FLUKE as the manufacturer.CHGCP-793An automated PG7000/PG9000 system with a PPC and AMH will use ATM as the minimum pressure when exercising in a test that is run in Absolute by ATM.3.00.42 (SP1) (2010.07.07)ADDCP-689Support alternate units of measure and temperature references for the Piston Cylinder effective area.ADDCP-775Added new instruments to the default database.CHGCP-786When...

    文章
  • CalTool for RPTs Free Utility

    CalTool for RPTs Free Utility (57.61 MB)TITLEVERUSE WITHDOCUMENTSCalTool™ for RPTs Free Utility1.10.0.252021.05.11PG7000, PPC2, PPC2+, PPC2 AF, PPC3, PPC4, PPCK, PPCK+, RPM1, RPM3, RPM4, PPCH, PPCH-G, molbox1, molbox RFMCalTool for RPTs uses an on line HTML help system that is installed with the program. Install and run CalTool then select the [Help] menu to access the help system.(Note: As a result of PC specific security settings the help may not display correctly when viewed over the Internet....

    文章
  • 6270A Embedded Software, Update by USB

    6270A Embedded Software, Update by USB (.zip)Additional Downloads:6270 PCM v104 USB (.zip)Click here to update by serial RS-232 port.TITLEUSE WITH6270A6270AThe updating of embedded software should only be performed after given specific instructions to do so from Technical Support or a Fluke Calibration Authorized Service Center.If the update isn't performed properly, your product may be inoperable until it is.Instructions to update by the USB port on the rear panel of the 6270AUpdating the PCM (Pressure...

    文章
  • 6270A Embedded Software, Update by Serial RS-232 Port

    6270A Embedded Software, Update by Serial RS-232 Port (.zip)Click here to update by USB.TITLEUSE WITH6270A6270AThe updating of embedded software should only be performed after given specific instructions to do so from Technical Support or a Fluke Calibration Authorized Service Center.If the update isn't performed properly, your product may be inoperable until it is.Instructions to update by the RS-232 serial port on the rear panel of the 6270AThe below procedure updates the main firmware. Updating...

    文章
  • 6003A Firmware Update

    6003A Firmware Update (.zip)TITLEUSE WITH6003AAllThe updating of embedded software should only be performed after given specific instructions to do so from Technical Support or a Fluke Calibration Authorized Service Center.If the update isn't performed properly, your product may be inoperable until it is.Instructions to update by USBInstallationPut the CD into the computer, wait for autorun and select “Software installation” and “Uploader” or start direct “install\freeware\uploader”.Uninstall...

    文章
  • 2271A Embedded Software, Update by USB

    2271A Embedded Software, Update by USB (zip)TITLEUSE WITH2271A2271AThe updating of embedded software should only be performed after given specific instructions to do so from Technical Support or a Fluke Calibration Authorized Service Center.If the update isn't performed properly, your product may be inoperable until it is.Instructions to update by the USB port on the rear panel of the 2271ABegin by clicking on the Get software button. Then download the zip file by clicking the 2271A v10x USB.zip...

    文章
  • Testing temperature uniformity on a flat-plate infrared calibrator

    There are a few instruments used to perform infrared (IR) thermometer and IR imager calibration. These instruments fall into two categories, cavities and flat-plates. To calculate the uncertainty in using these instruments, the temperature uniformity must be known. This is especially true with flat-plates. This uncertainty may be given in an instrument’s specification. However, there is not a standardized test method to test the uniformity of a flat-plate calibrator as there is with other classes...

    文章
  • 数据中心│保卫能耗绿线

    数据中心作为一个复杂的系统,存储着大量敏感信息和重要数据,又是能耗“大户”,需要应对不断提升的“绿”电、节能要求,全面及时的检测维护对于数据中心尤为重要,数据中心变“绿“要点有哪些? 电气系统温度检测 温度检测能帮助工程师发现潜在问题,如电气故障或过载问题,从而提前采取措施,降低火灾风险,同时优化系统运行,避免过度负荷和能源浪费,提高系统效率。...

    文章
  • 光伏系统 I-V 曲线测试:故障解决和安全提示

    随着光伏阵列的老化,系统性能可能因众多潜在原因而下降。有些原因是可以预见的,比如污染损耗和阵列的长期退化。还有一些则可能是意外情况,比如旁路二极管故障或模块破裂等。由于 I-V 曲线绘图仪能够记录光伏源的所有电流和电压工作点,这使得它具备识别光伏系统性能下降的各种症状的独特能力。 每个光伏模块的数据表都会提供一个模型 I-V 曲线,它会展示在标准测试条件...

    文章
  • 光伏电路性能测试最佳做法

    无论采用何种测试方法,对光伏电路性能进行评估时,您都必须掌握阵列辐照度和电池单元温度的分布情况。为确保准确解读 I-V 曲线,务必关注环境条件,因为辐照度或电池单元温度的快速波动可能导致 I-V 曲线测试出现误差。为了确保获得可靠的结果,我们应当选择适当的传感器类型和测试方法,例如 Fluke Solmetric PVA 1500 I-V 曲线绘图仪。 使用 Fluke Solmetric PVA 1500 IV 曲线绘图仪测量和分析光伏电路性能...

    文章
  • 如何分析 I-V 曲线

    要对光伏系统的 I-V 曲线进行分析,我们可以使用 I-V 曲线绘图仪,将实际测量的曲线与标准曲线或预测曲线进行对比,同时综合考虑各种环境因素,比如遮挡和温度等。 “光伏阵列故障排除流程图”是一份详尽的综合指南,它是根据丰富的现场实践经验、光伏模块可靠性方面的文献,以及国家可再生能源实验室 (NREL) 的专家建议编制而成。Fluke Solmetric PVA-1500 等 I-V 曲线绘图仪可为识别光伏系统中的硬件性能问题提供详尽的洞察。但是,遮挡、污染、辐照度、温度以及测量技术等因素会使光伏性能测量过程变得复杂。...

    文章
  • 具有 MecQ™ 的 Fluke ii910 声学成像仪提高了旋转设备及输送机系统维护效率

    旋转设备及输送机维护必须高效,以避免代价高昂的意外停机。这对于食品和饮料生产、物流仓储、汽车制造、采矿和原材料处理等行业尤为重要。具有 MecQ™ 模式的 Fluke ii910 声学成像仪提供了现代化的解决方案。该设备可检测出旋转设备及输送机系统中的潜在问题,以防止问题恶化。这使维护团队能够采取主动措施,更大限度提高系统性能。Fluke MecQ™ 模式可检测到可能意味着旋转设备及输送机系统出现问题的声音。亲自来看看吧!通过快速简便的声学成像进行视觉检测维护人员可以快速轻松地检测输送机系统中的潜在问题。具有...

    文章
  • Fluke 2000ACC 测试导线附件套装

    针对电线和电路跟踪以及故障排除应用,测试导线附件套装。

    产品
  • 使用热像仪对建筑和住宅进行检查

    了解用于住宅和建筑检查的热像仪。找到理想的暖通空调用热像仪。

    文章
  • 为什么在太阳能光伏装置中使用 CAT III 级钳表?

    用于安装、监测和测试光伏系统的一个关键工具是 Fluke 393 FC 太阳能钳表,其安全等级为 CAT III 1500 V/CAT IV 600 V,适用于包括太阳能装置的 CAT III 环境。

    文章
  • 万用表的历史

    万用表是谁发明的?从电流计和电压表到具有热成像和无线功能的数字万用表。福禄克万用表型号历史。

    文章
  • 局部放电测试和监测

    使用 Fluke ii910 声学成像仪进行局部放电测试和监测。了解如何执行局部放电测试步骤。

    文章
  • 局部放电的主要原因和类型

    局部放电定义了解局部放电如何发生、局部放电的原因以及 4 种主要的局部放电类型。

    文章
  • 如何提高气动工具的性能

    使用 Fluke ii900 声学成像仪提高气动工具性能。快速、轻松地诊断压缩空气管路中的压降和气流问题。

    文章
  • 诊断老旧电气系统的电能质量问题

    了解如何使用福禄克万用表和示波器诊断老旧电气系统中的电能质量问题。

    文章
  • Fluke Networks 工业连接器适配器套件

    Fluke Networks 工业连接器适配器套件

    产品
  • 用于 LinkIQ™ 的 Fluke Networks Remote ID #1/Wiremapper 备件

    用于 LinkIQ™ 的 Fluke Networks Remote ID #1/Wiremapper 备件

    产品
  • 钳形表与万用表的比较

    数字万用表本质上是一种具有一定电流测量能力的电压测量工具。钳形表基本上是一种具有一定电压能力的电流测量工具。两者是截然不同的仪表,各有优势。

    文章
  • 什么是钳形表?

    钳口测量电流,探头测量电压。将钳口集成到电表中,技术人员可以在电气系统的任何位置将钳口夹在电线、电缆和其他导体上,然后在不断开/断电的情况下测量电路中的电流。

    文章
  • Fluke TiX500 红外热像仪

    您对红外技术的观点将发生 240°的改变,答案就在您的眼前,即便目标并不在您眼前。高达640 x 480 的实测红外像素,实现精确测量,带有 MultiSharp™ 多点对焦功能和LaserSharp®激光自动对焦技术,温度量程达到-20°C至650°C。

    产品
  • Fluke SW90W FlukeView 示波表软件

    FlukeView软件为您的Fluke ScopeMeter测试工具添加PC电源

    产品
  • i3000s Flex-24 AC 电流钳型表, 610 mm

    i3000s Flex 是一款采用 Rogowski 原理的 AC 电流钳表。

    产品
  • Fluke CV300 ClirVu® 75 mm (3 in) 红外窗口

    使用福禄克红外窗口可提高工作效率,提高检查速度更快且更舒服,降低弧闪和触电风险,提高人员安全性,并降低预防性维护的时间和成本。CV300红外窗口的尺寸为75 mm,手动转动门锁。

    产品
  • Fluke Ti400 红外热像仪

    Fluke Ti400红外热像仪配有LaserSharp®激光自动对焦技术和触摸屏设计,分辨率为320×240像素,使每一次拍摄都能呈现一贯完美图像。卓越性能和良好的操控感完美结合,只有拿在手中的那一刻,您才更能体会。

    产品
  • Fluke 500 系列蓄电池分析仪软件下载

    Fluke 500 Series Battery Analyzers

    文章
  • 37X 召回

    福禄克自愿召回 2010 年 9 月 1 日至 2012 年 10 月 31 日之间生产的四种型号数字钳形表:373、374、375 和 376。

    文章